Welcome To Milennium Electronics Technologies Pvt. Ltd.

Our Products

Quasi Square Wave UPS

Special Features

Brings life to absolutely deep discharge batteries zero volt pick-up
Maximum charging power range
Any battery fit
Automatic charging selection technology
ME means healthier long living batteries
Total protection assured
Super styling

Saving Unlimited

Your ME Signature Inverter uses ultra modern Power Saver Technology (PFC) for saving in electricity bill. It has an inbuilt energy saver kit worth Rs. 1500/-
ME Signature Green Mode features switches off your inverter in situations of no load within 10 hours backup
mode.
Normal Inverter trickle charges your batteries even after full recharge whereas signature does oscillation charging after optimum recharge giving you a saving of 75% power.
The Inbuilt cooling fan Inside keeps it cool & enhances performance.
Signature’s high frequency technology prevents computer rebooting saving you from the perils of data loss.
Signature can run ½hp pump on 900 SG and higher model.
The most technologically advance signature charging not only reduces power bill but also makes battery life double now this is called Super Saver Inverter

signature inverter removebg preview

ME Quasi square wave UPS is Micro Computer based design ensures high reliability & ruggedness. “SIGNATURE” charging is most advanced, charging solution for healthy & longer life of battery. It is battery friendly & reduces running cost.

Quasi Square Wave UPS

ALL OEMs

S.No.

MODEL
Backup mode
SIGNATURE
(700VA)

SIGNATURE
( 900VA)

SIGNATUR
(1100VA-12V)

SIGNATURE (1500VA-24V)

SIGNATURE
(2200VA-24V)

1No Load to Full load O/P Voltage range
175V-260V
175V-260V
175V-260V
175V-260V
175V-260V
2
No Load Batt. Current
<1.5A<2.7A

<=3A<=3A<=3A
3
Running Load Batt. Current
(42±2)A
(52±2)A(66±2)A(48±2)A
(65±2)A
4Over Load Batt. current
(46±2)A
(56±2)A
(70±2)A
(50±2)A
(68±2)A
5O/P Frequency {N/L & F/L}
(50.0±.5)HZ
(50.0±.5)HZ
(50.0±.5)HZ
(50.0±.5)HZ
(50.0±.5)HZ
6Fan Working test at [Load/Temp.]
>30%
>30%
>30%
>30%
>30%
7Running bulb load
560W min.
720W min.
880W min.
1200W min.
1600W min.
8Low batt. Alarm (FLAT PLETE BATT.)MODE
(11.00V±.2)V
(11.00V±.2)V
(11.00V±.2)V
(11.00V±.2)V
(11.00V±.2)V
9Low batt. shutdown
(10.70V±.2)V
(10.70V±.2)V
(10.70V±.2)V
(10.70V±.2)V
(10.70V±.2)V
10Re-tries during Batt. Low cut off. UPS
00000
11Re-tries during Batt. Low cut off. Normal
11111
12Manual reset during low battery (Using On/Off switch)
33333
13Re-tries during Over Load UPS
00000
14Re-tries during Over Load INV
55555
S.N0Mains AC mode
1Mains AC Low cut UPS mode(175±10)V
(175±10)V
(175±10)V
(175±10)V
(175±10)V
2Low cut recovery UPS mode(9-12)V
(9-12)V
(9-12)V
(9-12)V
(9-12)V
3Mains AC High cut UPS mode(265±10)V
(265±10)V
(265±10)V
(265±10)V
(265±10)V
4High cut recovery UPS mode(9-12)V
(9-12)V
(9-12)V
(9-12)V
(9-12)V
5Mains AC Low cut Normal mode(100±10)V
(100±10)V
(100±10)V
(100±10)V
(100±10)V
6Low cut recovery Normal mode(9-12)V
(9-12)V
(9-12)V
(9-12)V
(9-12)V
7Mains AC High cut Normal mode(290±10)V
(290±10)V
(290±10)V
(290±10)V
(290±10)V
8High cut recovery Normal mode(9-12)V
(9-12)V
(9-12)V
(9-12)V
(9-12)V
9Battery charging voltage (boost)(14.3±.2)V
(14.3±.2)V
(14.3±.2)V
(28.6±.2)V
(28.6±.2)V
10Battery charging oscillation(13.2-13.7)V
(13.2-13.7)V
(13.2-13.7)V
(26.4-27.4)V
(26.4-27.4)V
11Battery charging current(11±1)A
(11±1)A
(11±1)A
(11±1)A
(11±1)A
12Mains Fuse Blown testAvl.
Avl.
Avl.
Avl.
Avl.
S.No.
Visual Indications
1Self test
all LED(without backup) 1time
all LED(without backup) 1time
all LED(without backup) 1time
all LED(without backup) 1time
all LED(without backup) 1time
2On/Off switch off (With mains within range)
mains LED blinking
mains LED blinking
mains LED blinking
mains LED blinking
mains LED blinking
3On/Off switch on (With mains within range)
LED glow
LED glow
LED glow
LED glow
LED glow
4Mains out of range
LED off
LED off
LED off
LED off
LED off
5Battery charging
LED Blinking
LED Blinking
LED Blinking
LED Blinking
LED Blinking
6Battery charged
LED CG
LED CG
LED CG
LED CG
LED CG
7Backup present
LED cont.glow
LED cont.glow
LED cont.glow
LED cont.glow
LED cont.glow
8Low battery occurs
LED blink with 90sec.
LED blink with 90sec.
LED blink with 90sec.
LED blink with 90sec.
LED blink with 90sec.
9Low battery shutdown
LED con.glow
LED con.glow
LED con.glow
LED con.glow
LED con.glow
10Overload occurs
LED Blinking
LED Blinking
LED Blinking
LED Blinking
LED Blinking
11Overload shutdown
LED con.glow
LED con.glow
LED con.glow
LED con.glow
LED con.glow
12Shortcircuit occurs
LED con.glow
LED con.glow
LED con.glow
LED con.glow
LED con.glow
13Shortcircuit shutdown
LED con.glow
LED con.glow
LED con.glow
LED con.glow
LED con.glow
14Mains fuse blown
main LED CG
main LED CG
main LED CG
main LED CG
main LED CG
15TSC protection
CH.LED CG
CH.LED CG
CH.LED CG
CH.LED CG
CH.LED CG
16Overtemperature shutdown
all LED(without backup led) CG
all LED(without backup led) CG
all LED(without backup led) CG
all LED(without backup led) CG
all LED(without backup led) CG
17AC back feed
Avl.
Avl.
Avl.
Avl.
Avl.
S.No.
Audio Indications (Buzzer)
1Self test
1 Beep
1 Beep
1 Beep
1 Beep
1 Beep
2Short circuit occurs
CB
CB
CB
CB
CB
3Short circuit shutdown
CB
CB
CB
CB
CB
4Overload occurs
BP-BP
BP-BP
BP-BP
BP-BP
BP-BP
5Overload shutdown
NB
NB
NB
NB
NB
6Low battery occurs
bp-bp with 90sec.
bp-bp with 90sec.
bp-bp with 90sec.
bp-bp with 90sec.
bp-bp with 90sec.
7Low battery shutdown
NB
NB
NB
NB
NB
8Overtemperature shutdown
CB
CB
CB
CB
CB
9AC back feed
CB
CB
CB
CB
CB
10Mains fuse blown
CB
CB
CB
CB
CB
11Buzzer mute option
By on/off switch
By on/off switch
By on/off switch
By on/off switch
By on/off switch