High-performance energy solutions to power your world — inverters, batteries, solar panels & accessories.
Smart power, enhanced safety & ultimate efficiency
Charging at 12A, 120V AC. Wide input range: 100V–300V with PFC energy-saving technology.
Reduces electricity bills with advanced oscillation charging and automatic voltage cut-off.
Runs ½ HP Tullu water pumps efficiently on 900VA and above models.
High-efficiency fan provides better cooling and extends product life.
Auto shutdown at high temperature for added safety and protection.
Prevents system reboot during power transition with stable high-frequency tech.
Supports Branded/Non-Branded, Tubular, Flat Plate & SMF batteries.
Custom set voltage & current based on power cut duration & battery age.
Short-circuit, phase reversal, back feed, reverse battery & voltage protections included.
Gravity Profile Management adjusts performance for new or old batteries.
UPS shuts down in 10 hours at no load in backup mode, saving power and improving battery life.
Emergency Lighting
Security
Utility
Universal
Telecom
| S.No. | PARAMETERS | UNIT | COMMANDEER SERIES | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | Model name | 875 | 975 | 1175 | 1475 | 1875 | 2575 | |||
| 2 | System rating (Name Plate) | VA | 500VA | 700VA | 9000VA | 1100VA | 1500VA | 2200VA | ||
| 3 | Operating DC voltage | 12 | 24 | |||||||
| 4 | Technology Based | Micro Controller Based Technology | ||||||||
| 5 | Output Wave From | Quasi Sinusoidal Wave | ||||||||
| 6 | Output voltage on inverter mode | Vac | 220V ± 10V | |||||||
| 7 | Output phase | Single Phase | ||||||||
| 8 | Output Frequency on Inverter | Hz | 50Hz ± 0.1Hz | |||||||
| 9 | Crest Factor | 3:1 | ||||||||
| 10 | Efficiency | >85°C | ||||||||
| 11 | Cooling Fan Off at temp | °C | 50°C | |||||||
| 12 | Battery low voltage alarm per battery | Vdc | 11V ± 0.2V | |||||||
| 13 | Battery low voltage cut per battery | Vdc | 10.7V ± 0.2v | |||||||
| 14 | Max Battery charging voltage by grid per battery | Vdc | 14.4V | |||||||
| 15 | Max Battery charging current by grid | Adc | Up to 13A | |||||||
| 15 | Input Voltage Range (Inverter Mode) | Vac | 100–290V ± 10V | |||||||
| 16 | Input Voltage Range (UPS Mode) | Vac | 180–260V ± 10V | |||||||
| 17 | Input current at no load at Nominal Battery Voltage | Adc | < 1.8A Max | |||||||
| 18 | Noise @ 1 meter | dB | < 40 dB | |||||||
| 19 | Protections | Short Circuit, Phase reversal , AC Back feed , Thysistor Short-Circuit , Reverse Batttery high & Low Voltage Protection | ||||||||
| 20 | Indication LEDs | Self Test , Out of range , Battery Charging , Backup , Low Battery , Shutdown , Overload , Short Circuit , Over Temperature | ||||||||
| 21 | Changeover: Inverter to Mains (UPS Mode) | ms | < 10 ms | |||||||
| 22 | Changeover: Inverter to Mains (Normal Mode) | ms | < 10 ms | |||||||
| 23 | Changeover: Mains to Inverter (UPS Mode) | ms | < 10 ms | |||||||
| 24 | Changeover: Mains to Inverter (Normal Mode) | ms | < 30 ms | |||||||
| 25 | Input Protection | Push-to-reset Circuit Breaker | ||||||||
| 26 | Mode Selection | UPS/Inverter, Charging Voltage & Amp HI/LO | ||||||||
| MODEL NAME | 875 | 975 | 1175 | 1475 | 1875 | 2575 |
|---|---|---|---|---|---|---|
| Product Dimension (L×W×H) in MM | 275×195×110 | 275×250×110 | 333×275×132 | |||
| Packaging Box Dimension (L×W×H) | 328×330×185 | 360×340×180 | 387×405×215 | |||
| Net Weight (AL) | 6.105 Kg | 6.780 Kg | 7.830 Kg | 9.125 Kg | 13.615 Kg | 16.060 Kg |
| Gross Weight (AL) | 6.700 Kg | 7.510 Kg | 8.310 Kg | 9.805 Kg | 14.685 Kg | 17.095 Kg |
| Net Weight (CU) | 6.800 Kg | 7.355 Kg | 7.970 Kg | 9.030 Kg | 13.800 Kg | 16.500 Kg |
| Gross Weight (CU) | 7.800 Kg | 8.065 Kg | 8.540 Kg | 9.700 Kg | 14.600 Kg | 17.100 Kg |