Our Products

High-performance energy solutions to power your world — inverters, batteries, solar panels & accessories.

COMMANDER Series

External Battery UPS

Elegant UPS Features

Smart power, enhanced safety & ultimate efficiency

Input & Charging

Charging at 12A, 120V AC. Wide input range: 100V–300V with PFC energy-saving technology.

Oscillation Charging System

Reduces electricity bills with advanced oscillation charging and automatic voltage cut-off.

Water Pump Compatible

Runs ½ HP Tullu water pumps efficiently on 900VA and above models.

Superior Cooling

High-efficiency fan provides better cooling and extends product life.

Temperature Sensor

Auto shutdown at high temperature for added safety and protection.

High Frequency Stability

Prevents system reboot during power transition with stable high-frequency tech.

Universal Battery Compatibility

Supports Branded/Non-Branded, Tubular, Flat Plate & SMF batteries.

Automatic Charging Control

Custom set voltage & current based on power cut duration & battery age.

Complete Protection

Short-circuit, phase reversal, back feed, reverse battery & voltage protections included.

GPM Technology

Gravity Profile Management adjusts performance for new or old batteries.

Green Mode

UPS shuts down in 10 hours at no load in backup mode, saving power and improving battery life.

Emergency Lighting

Security

Utility

Universal

Telecom

SINEWAVE HOME UPS - Technical Specifications

S.No. PARAMETERS UNIT COMMANDEER SERIES
1 Model name 875 975 1175 1475 1875 2575
2 System rating (Name Plate) VA 500VA 700VA 9000VA 1100VA 1500VA 2200VA
3 Operating DC voltage 12 24
4 Technology Based Micro Controller Based Technology
5 Output Wave From Quasi Sinusoidal Wave
6 Output voltage on inverter mode Vac 220V ± 10V
7 Output phase Single Phase
8 Output Frequency on Inverter Hz 50Hz ± 0.1Hz
9 Crest Factor 3:1
10 Efficiency >85°C
11 Cooling Fan Off at temp °C 50°C
12 Battery low voltage alarm per battery Vdc 11V ± 0.2V
13 Battery low voltage cut per battery Vdc 10.7V ± 0.2v
14 Max Battery charging voltage by grid per battery Vdc 14.4V
15 Max Battery charging current by grid Adc Up to 13A
15 Input Voltage Range (Inverter Mode) Vac 100–290V ± 10V
16 Input Voltage Range (UPS Mode) Vac 180–260V ± 10V
17 Input current at no load at Nominal Battery Voltage Adc < 1.8A Max
18 Noise @ 1 meter dB < 40 dB
19 Protections Short Circuit, Phase reversal , AC Back feed , Thysistor Short-Circuit , Reverse Batttery high & Low Voltage Protection
20 Indication LEDs Self Test , Out of range , Battery Charging , Backup , Low Battery , Shutdown , Overload , Short Circuit , Over Temperature
21 Changeover: Inverter to Mains (UPS Mode) ms < 10 ms
22 Changeover: Inverter to Mains (Normal Mode) ms < 10 ms
23 Changeover: Mains to Inverter (UPS Mode) ms < 10 ms
24 Changeover: Mains to Inverter (Normal Mode) ms < 30 ms
25 Input Protection Push-to-reset Circuit Breaker
26 Mode Selection UPS/Inverter, Charging Voltage & Amp HI/LO

Model Dimensions & Weight Table

MODEL NAME 875 975 1175 1475 1875 2575
Product Dimension (L×W×H) in MM 275×195×110 275×250×110 333×275×132
Packaging Box Dimension (L×W×H) 328×330×185 360×340×180 387×405×215
Net Weight (AL) 6.105 Kg 6.780 Kg 7.830 Kg 9.125 Kg 13.615 Kg 16.060 Kg
Gross Weight (AL) 6.700 Kg 7.510 Kg 8.310 Kg 9.805 Kg 14.685 Kg 17.095 Kg
Net Weight (CU) 6.800 Kg 7.355 Kg 7.970 Kg 9.030 Kg 13.800 Kg 16.500 Kg
Gross Weight (CU) 7.800 Kg 8.065 Kg 8.540 Kg 9.700 Kg 14.600 Kg 17.100 Kg